TQCSheen Adezyon Pull Off Test Cihazı - Manual

 
Positest Adhesion Tester - Manual 
PRODUCT DESCRIPTION
The new PosiTest Adhesion Tester measures adhesion
substrates. There is a manual and an automatic model
available.

Both models have a hydraulic pump. The pump of the
automatic version is electronically controlled and
applies smooth and continuous pull-off pressure. This
greatly reduces user effort and the risk of influencing the pulling process.
Self-aligning aluminum dollies enable
accurate measurements on smooth or uneven surfaces
The internal memory of the Manual version stores maximum pull-off pressure,
dolly size for up to 200 pulls. The automatic version stores maximum pull-off
pressure, rate of pull, test duration, dolly size, pass/fail,nature of fracture and
user notes for 100,000 pulls in up to 1,000 batches in itsinternal memory and pull rate,
pull limit and hold time are user-adjustable with the impact and scratch resistant color
touch screen with keypad for operation with or without gloves.
Every PosiTest Adhesion Tester pressure system is calibrated and certified to ± 1%
accuracy using a NIST traceable load cel. Evaluating measured values on PC is possible
by using an adapter and PC-software.

STANDARDS

Conforms to international standards including ASTM D4541/D7234, ISO 4624/16276-1,
AS/NZS 1580.408.5 and others. Look up the appropriate standard for a correct
execution of the test.

FEATURES

.Self-aligning aluminum dolly enables accurate measurements on smooth or
 uneven surfaces
.Internal memory
.Compatible with PosiSoft desktop software
.Environmentally sealed enclosure – weatherproof, dustproof and shockproof
 meets or exceeds IP65

SCOPE OF SUPPLY

Positest Adhesion Tester -Manual
LD9332: 20 mm dollies (20), 20 mm cutting tool and 20 mm stand off
LD9333: 50 mm dollies (8), 50 mm cutting tool and 50 mm stand off
Manual Adhesion Tester,
built-in rechargeable NiMH battery with charger
abrasive pad
glue with mixing sticks and palettes

Positest Adhesion Tester-Automatic

LD9330: 20 mm dollies (20), 20 mm cutting tool and 20 mm stand off
LD9331: 50 mm dollies (8), 50 mm cutting tool and 50 mm stand off
Automatic Adhesion Tester
built-in rechargeable NiMH battery with charger
abrasive pad
glue with mixing sticks and palettes

• cotton swabs
• USB cable
• PosiSoft Software
• instruction booklet and video
• Certificate of Calibration traceable to NIST
• two-year warranty
• sturdy, lightweight carrying case

ORDERING INFORMATION

LD9332 Defelsko Positest ATM20 Manual Adhesion tester with 20 mm dollies
LD9333 Defelsko Positest ATM50 Manual Adhesion tester with 50 mm dollies
LD9330 Defelsko Positest ATA20 Automatic Adhesion tester with 20 mm dollies
LD9331 Defelsko Positest ATA50 Automatic Adhesion tester with 50 mm dollies

ACCESSORIES

LD9250 TQC Dolly Drill for Adhesion Test
LD9304 20 mm accessories kit (for LD9331 and LD9333)
LD9305 50mm accessories kit (for LD9330 and LD9332)
LD9306 DeFelsko 20 mm dollies, 10 pieces
LD9307 DeFelsko 50 mm dollies, 4 pieces
LD9308 Glue set for PosiTest AT
LD9310 Dollies 20mm for PosiTest AT, 50 pieces
LD9312 20mm hole saw for PosiTest AT
LD9313 DeFelsko 10mm dollies, 10 pcs (only suitable for 20mm model)
LD9314 DeFelsko 14mm dollies, 10 pcs (only suitable for 20mm model)
LD9320 MC Quick Solid glue set
LD9321 Spare Glue cartridge MC-Quick Solid
LD9022 Araldite Epoxy Adhesive 2012 2x25ml

SPECIFICATIONS

 Manual Adhesion Tester  Art. No: LD9332
0.7 – 20 MPa
100 – 3000 psi
 Art. No: LD9333
0.4 – 3.5 MPa
50 – 500 psi
 Automatic Adhesion Tester  Art. No: LD9330
0.7 – 24 MPa
100 – 3500 psi
100 – 7550 N
 Art. No: LD9331
0.4 – 3.8 MPa
50 – 560 psi
100 – 7550 N
 Dolly  20 mm  50 mm 
 Typical application  Coatings on metal  Coatings on wood, concrete and
plastic
 Resolution  0.01 MPa (1 psi)  
 Accuracy  +/- 1% Full Scale  


USE

With this method, a loading fixture commonly called a dolly or stud supplied as
smooth steel or aluminium must be cleaned before it is glued with epoxy or acrylic
adhesives to the surface. The coating surface must also be cleaned. Roughen the
bonding surface of the dolly either with sandpaper or light abrasive blasting. The
adhesive must cure for the amount of time recommended by the manufacturer.
This can be several hours to a day, depending on the adhesive and the temperature.
A critical step in the test procedure is positioning the dolly onto the surface. Avoid any
movement, especially twisting, that can result in stress discontinuities during the pull testing.
Wipe away any excess adhesive with a cotton swab once the dolly is in place. Place the self
aligning adapter over the dolly by lifting the quick coupling ring upwards and when in place to
release it. The pull is perpendicular to the surface, so tensile strength is being measured.
The manual AT load to the dolly should be increased continuously and smoothly at a rate
not to exceed 1 MPa/s (145 psi/s). In case of the automatic AT-A this is done by continued
build up provided by the unit. Keep applying the load until failure occurs
(or until the maximum force has been applied).

SPECIAL CARE

• Though robust in design, this instrument is precision-machined. Never drop it or knock it over
• Always clean the instrument after use.
• Clean the instrument using a soft dry cloth. Never clean the instrument by any mechanical
  means such as a wire brush or abrasive paper. This may cause, just like the use of aggressive
  cleaning agents, permanent damage.
• Do not use compressed air to clean the instrument.
• Always keep the instrument in its case when not in use.
• We recommend annual calibration

SAFETY PRECAUTIONS

• Not suitable to be put in the sun or in the high light
• Avoid using it in over-high or over-low temperature environment
• Avoid humidity

DISCLAIMER

The right of technical modifications is reserved.
The information given in this sheet is not intended to be exhaustive and any person using
the product for any purpose other than that specifically recommended in this sheet without
first obtaining written confirmation from us as to the suitability of the product for the intended
purpose does so at his own risk. Whilst we endeavour to ensure that all advice we give about
the product (whether in this sheet or otherwise) is correct we have no control over either the
quality or condition of the product or the many factors affecting the use and application of the
product. Therefore, unless we specifically agree in writing to do so, we do not accept any
liability whatsoever or howsoever arising for the performance of the product or for any loss
or damage (other than death or personal injury resulting from our negligence) arising out of
the use of the product. The information contained in this sheet is liable to modification from
time to time in the light of experience and our policy of continuous product development.







































































































 
      Yazıcı Dostu Sayfa
Ayrıntılı Bilgi Formu
Hizmetlerimiz ve diğer konular hakkında bilgi almak için bizimle irtibata geçebilirsiniz.


Ad Soyad
:  
Firma Adı
:  
E-Mail :  
Telefon
:  
Şehir
:  
Mesaj
:  
        
Bu Sayfayı Arkadaşına Gönder
Sayfayı arkadaşınıza göndermek için lütfen aşağıdaki bilgileri doldurunuz.


Ad Soyad
:  
Ark. Adı
:  
Ark. E-Mail
:  
Mesaj
: